Overview Product Description High Sensitivity & High Resolution Portable Raman Spectrometer DTR2500 Application:Nanopart
Overview
DTR2500 is a Raman spectrometer developed by Drawell for more than 20 years. After 5 years, it has developed a brand-new, optimized and designed high-sensitivity Raman spectrometer with
breakthrough characteristics. It has ultra-small and ultra-light,
High resolution, high sensitivity, high reliability, etc. DTR2500 adopts Optosky's latest full free space optical path technology,which increases the Raman signal collection efficiency by nearly 4 times, thereby increasing the sensitivity by 4 times.
The DTR2500 Raman spectrometer is very suitable forlaboratory scientific research. It is small in size, high reliability,easy to measure, and the detection results are accurate andreliable. The excellent low stray light design of DTR2500 makes it easy to use. The multi-function software randomly distributed by DTR2500 has been strictly tested by hundreds of scientists aroundthe world and collected their improvement opinions. After nearly a hundred versions of updates, the function is very complete and stable, which is very suitable for the development of Raman research.
Note:
Tested according to the American National Standard ASTM E2529-06;
FAQ
Basic Info.
Model NO. | DTR2500 |
Wavelengths | Infrared Spectrometer |
Dispersive Element | / |
Light Number | / |
Certification | ISO9001, CE |
Customized | Customized |
Spectral Intensity | (±5% (in 5 -40ºC) |
-1 Spectral Range (Cm ) | 250-2700 |
Temperature Reliability | Spectral Shift < 1 Cm -1 (10-40ºC) |
Spectral Reliability | σ/μ < 0.5% (Cot 8 Hours) |
Model | Ultra-Sensitive Linear Array Detector |
Spectral Range | 200-1100 Nm |
Snr | >1300:1 |
-1 Resolution (Cm ) | 4-6 |
Work Humidity | < 95% |
Work Temperature | -10 to 45ºC |
Weight | 390 G |
Dimension(L*W*H) | Without Probe:119.2X89X35 mm |
Interface | USB 2.0 |
Transport Package | Wooden Box |
Specification | 57*27*56cm |
Trademark | Drawell |
Origin | Chongqing, China |
Production Capacity | 100pieces/Month |
Product Description
Product Description
High Sensitivity & High Resolution Portable Raman Spectrometer DTR2500
- Feature
- Full free space design, super
sensitivity; - Ultra-high sensitivity detector;
- Ultra-low noise circuit;
- Ultra-light, ultra-small, ultra reliable;
- Powerful spectral analysis software;
- Eliminate fluorescent background;
- Peak search and display;
- USB 2.0;
- Friendly man-machine interface.
DTR2500 is a Raman spectrometer developed by Drawell for more than 20 years. After 5 years, it has developed a brand-new, optimized and designed high-sensitivity Raman spectrometer with
breakthrough characteristics. It has ultra-small and ultra-light,
High resolution, high sensitivity, high reliability, etc. DTR2500 adopts Optosky's latest full free space optical path technology,which increases the Raman signal collection efficiency by nearly 4 times, thereby increasing the sensitivity by 4 times.
The DTR2500 Raman spectrometer is very suitable forlaboratory scientific research. It is small in size, high reliability,easy to measure, and the detection results are accurate andreliable. The excellent low stray light design of DTR2500 makes it easy to use. The multi-function software randomly distributed by DTR2500 has been strictly tested by hundreds of scientists aroundthe world and collected their improvement opinions. After nearly a hundred versions of updates, the function is very complete and stable, which is very suitable for the development of Raman research.
Model | Spectral Range (cm-1) | Resolution (cm-1) |
DTR2500-27 | 250-2700 | 4-6 |
DTR2500-40 | 200-4000 | 7-10 |
Tested according to the American National Standard ASTM E2529-06;
DTR2500 | |||
Interface | USB 2.0 | ||
Integration time | 4ms - 120s | ||
Voltage | DC 5V±5% | ||
Work temperature | -10-45ºC | ||
Work humidity | < 95% | ||
Dimension(L*W*H) | Without probe : 119.2x89x35 mmWith probe : 139x89x35 mm | ||
Weight | 390 g | ||
Reliability | |||
Spectral reliability | σ/μ < 0.5% (COT 8 hours) | ||
Temperature reliability | Spectral shift < 1 cm -1 (10-40ºC) | ||
Spectral intensity | (±5% (in 5 -40ºC) | ||
Optical parameter | |||
-1 Spectral range (cm ) | 250-2700 | / | 200-4000 |
-1 Resolution (cm ) | 4-6 | / | 7-10 |
SNR | >1300:1 (918 cm-1of Acetonitrile,4sIntergation, 130mW) | ||
Detector | |||
Model | Ultra-sensitive linear array detector | ||
Spectral range | 200-1100 nm | ||
Effective pixels | 2048 pixels | ||
Dynamic range | 50000: 1 | ||
Laser | |||
Center wavelength | 785±0.5nm | ||
Half width | 0.08 nm | ||
Maximum output power | >300 mW, the actual output power software can be set | ||
Minimum power output adjustment | 1mW | ||
Power stability | σ/μ <±0.2% | ||
Raman probe | |||
Rayleigh Scatter Resistance | 6 mm | ||
Operating Distance(OD) | OD>8 | ||
NA | 0.3 | ||
Aperture | 7mm |